Vulnerabilities in pkg:maven/org.jenkins-ci.plugins/xray-connector
PACKAGECVE-2021-21652 is a HIGH (CVSS 7.1) csrf vulnerability vulnerability (CWE-352: Cross-Site Request Forgery (CSRF)) affecting Xray connector libraries in the Maven ecosystem. The issue involves csrf vulnerability in jenkins xray - test management for jira plugin allows capturing credentials. Remediation is available by upgrading affected packages to version 2.4.1.
pkg:maven/org.jenkins-ci.plugins/xray-connector
Vulnerability advisories affecting package pkg:maven/org.jenkins-ci.plugins/xray-connector. Select an advisory below to view technical details or fixes.
| Advisory ID | CVE / NVD | Severity | Summary |
|---|---|---|---|
| GHSA-rrvg-2c69-p9rf | CVE-2021-21652 | HIGH | CSRF vulnerability in Jenkins Xray - Test Management for Jira Plugin allows capturing credentials |
| GHSA-5557-j87h-cvf4 | CVE-2021-21653 | MODERATE | Missing Authorization in jenkins xray-connector |
CVE-2021-21652 at a Glance
Security Impact
CVSS: 7.1
The security impact metrics below are parsed directly from the CVSS v3.1 vector string (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:L/A:N).
How to Fix CVE-2021-21652
To remediate this vulnerability, upgrade all affected Xray connector dependencies to a patched release. Both direct and transitive dependencies should be checked, as frameworks or security libraries may pull in vulnerable versions transitively.
<dependency>
<groupId>org.jenkins-ci.plugins</groupId>
<artifactId>xray-connector</artifactId>
<version>2.4.1</version>
</dependency>
Run the following command in your project directory to verify that all resolved dependencies use the patched release:
mvn dependency:tree -Dincludes=org.jenkins-ci.plugins
How to Check if You Are Affected
To determine whether your Java application is affected by CVE-2021-21652, inspect your build dependencies using the Maven Dependency Plugin:
mvn dependency:tree -Dincludes=org.jenkins-ci.plugins
Analyze the terminal output to locate any version of Xray connector in your dependency tree. If any resolved version matches the vulnerable ranges listed in the table below (for example, versions earlier than 2.4.1), your application is affected.
Note: The mvn dependency:tree -Dincludes=org.jenkins-ci.plugins command inspects the resolved dependency graph declared in your project's POM files; it does not perform automated security scanning or inspect runtime dynamic classpaths. Always verify runtime container classpaths and shaded JARs.
Technical Details
Vulnerability Mechanism & Technical Analysis
This vulnerability is classified under CWE-352: Cross-Site Request Forgery (CSRF), where the web application does not, or cannot, sufficiently verify whether a request was intentionally provided by the user who sent the request, which could have originated from an unauthorized actor. In Xray connector, software state validation or input boundaries are circumvented during processing. Review the official source advisory statement below for specific affected components, classes, and reproduction details.
Source Advisory Statement
CVE-2021-21652 Affected Xray connector Versions
1 component(s)| Product / Package | Ecosystem | Affected Versions | Fixed Version |
|---|---|---|---|
|
org.jenkins-ci.plugins:xray-connector
|
Maven |
< 2.4.1
|
2.4.1
|
References
Frequently Asked Questions
What is CVE-2021-21652?
Which Xray connector versions are affected?
What version fixes CVE-2021-21652?
Is xray-connector affected?
What is the CVSS score of CVE-2021-21652?
What CWE is associated with CVE-2021-21652?
How can I check Maven dependencies for CVE-2021-21652?
Machine-readable OSV JSON
OSV v1.5 Schema
{
"schema_version" : "1.4.0",
"id" : "GHSA-rrvg-2c69-p9rf",
"modified" : "2023-10-27T14:35:10Z",
"published" : "2021-06-16T17:28:58Z",
"aliases" : [ "CVE-2021-21652" ],
"summary" : "CSRF vulnerability in Jenkins Xray - Test Management for Jira Plugin allows capturing credentials",
"details" : "Jenkins Xray - Test Management for Jira Plugin 2.4.0 and earlier does not require POST requests for a connection test method, resulting in a cross-site request forgery (CSRF) vulnerability.\n\nThis vulnerability allows attackers to connect to an attacker-specified URL using attacker-specified credentials IDs obtained through another method, capturing credentials stored in Jenkins.\n\nJenkins Xray - Test Management for Jira Plugin 2.4.1 requires POST requests for the affected connection test method.",
"severity" : [ {
"type" : "CVSS_V3",
"score" : "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:L/A:N"
} ],
"affected" : [ {
"package" : {
"ecosystem" : "Maven",
"name" : "org.jenkins-ci.plugins:xray-connector"
},
"ranges" : [ {
"type" : "ECOSYSTEM",
"events" : [ {
"introduced" : "0"
}, {
"fixed" : "2.4.1"
} ]
} ]
} ],
"references" : [ {
"type" : "ADVISORY",
"url" : "https://nvd.nist.gov/vuln/detail/CVE-2021-21652"
}, {
"type" : "PACKAGE",
"url" : "https://github.com/jenkinsci/xray-connector-plugin"
}, {
"type" : "WEB",
"url" : "https://www.jenkins.io/security/advisory/2021-05-11/#SECURITY-2251%20(1)"
} ],
"database_specific" : {
"cwe_ids" : [ "CWE-352" ],
"severity" : "HIGH",
"github_reviewed" : true,
"github_reviewed_at" : "2021-05-19T19:12:26Z",
"nvd_published_at" : "2021-05-11T15:15:00Z"
}
}