CVE-2017-6865: Software Security Vulnerability Vulnerability

MODERATE
Advisory Identifier: GHSA-8jhv-ch7h-fqpj
CVSS 6.5
CWE-20
Published
Advisory Summary

CVE-2017-6865 is a MODERATE (CVSS 6.5) security vulnerability vulnerability (CWE-20: Improper Input Validation) affecting Software libraries in the Maven ecosystem. The weakness occurs when the product receives input or data, but it does not validate or incorrectly validates that the input has the properties that are required to process the data safely and correctly.. Remediation is available in the latest vendor maintenance releases.

CVE-2017-6865 at a Glance

CVE Identifier CVE-2017-6865
GHSA Identifier GHSA-8jhv-ch7h-fqpj
Severity MODERATE
CVSS v3.1 Base Score 6.5
CWE Classification CWE-20: Improper Input Validation
Affected Product Software
Package Ecosystem Maven
Published Date
Last Updated

Security Impact

CVSS: 6.5

The security impact metrics below are parsed directly from the CVSS v3.1 vector string (CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

Attack Vector Adjacent (AV:A)
Attack Complexity Low (AC:L)
Privileges Required None (PR:N)
User Interaction None (UI:N)
Scope Unchanged (S:U)
Confidentiality None (C:N)
Integrity None (I:N)
Availability High (A:H)

How to Fix CVE-2017-6865

To remediate this vulnerability, upgrade all affected Software dependencies to a patched release. Both direct and transitive dependencies should be checked, as frameworks or security libraries may pull in vulnerable versions transitively.

Verify Direct and Transitive Dependencies

Run the following command in your project directory to verify that all resolved dependencies use the patched release:

mvn dependency:tree

How to Check if You Are Affected

To determine whether your Java application is affected by CVE-2017-6865, inspect your build dependencies using the Maven Dependency Plugin:

mvn dependency:tree

Analyze the terminal output to locate any version of Software in your dependency tree. If any resolved version matches the vulnerable ranges listed in the table below (for example, versions earlier than the patched release), your application is affected.

Note: The mvn dependency:tree command inspects the resolved dependency graph declared in your project's POM files; it does not perform automated security scanning or inspect runtime dynamic classpaths. Always verify runtime container classpaths and shaded JARs.

Technical Details

Vulnerability Mechanism & Technical Analysis

This vulnerability is classified under CWE-20: Improper Input Validation, where the product receives input or data, but it does not validate or incorrectly validates that the input has the properties that are required to process the data safely and correctly. In Software, software state validation or input boundaries are circumvented during processing. Review the official source advisory statement below for specific affected components, classes, and reproduction details.

Source Advisory Statement

A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover.

References

Frequently Asked Questions

What is CVE-2017-6865?
CVE-2017-6865 is a security vulnerability in Software classified as a security vulnerability vulnerability under CWE-20: Improper Input Validation.
Which Software versions are affected?
Affected versions include releases prior to current release patches.
What version fixes CVE-2017-6865?
Upgrading to current release patches (or the latest patched release for your respective branch) resolves the vulnerability.
What is the CVSS score of CVE-2017-6865?
CVE-2017-6865 has a CVSS v3.1 base score of 6.5 (MODERATE) with vector string CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H.
What CWE is associated with CVE-2017-6865?
CVE-2017-6865 is classified under CWE-20: Improper Input Validation (The product receives input or data, but it does not validate or incorrectly validates that the input has the properties that are required to process the data safely and correctly.).
How can I check Maven dependencies for CVE-2017-6865?
Run the dependency tree command: 'mvn dependency:tree'. This command lists direct and transitive dependencies in your build configuration so you can verify if a vulnerable version is resolved.
Machine-readable OSV JSON OSV v1.5 Schema
Normalized schema output
{
  "schema_version" : "1.4.0",
  "id" : "GHSA-8jhv-ch7h-fqpj",
  "modified" : "2022-05-14T01:18:15Z",
  "published" : "2022-05-14T01:18:15Z",
  "aliases" : [ "CVE-2017-6865" ],
  "details" : "A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover.",
  "severity" : [ {
    "type" : "CVSS_V3",
    "score" : "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
  } ],
  "affected" : [ ],
  "references" : [ {
    "type" : "ADVISORY",
    "url" : "https://nvd.nist.gov/vuln/detail/CVE-2017-6865"
  }, {
    "type" : "WEB",
    "url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf"
  }, {
    "type" : "WEB",
    "url" : "https://www.securityfocus.com/bid/98366"
  } ],
  "database_specific" : {
    "cwe_ids" : [ "CWE-20" ],
    "severity" : "MODERATE",
    "github_reviewed" : false,
    "github_reviewed_at" : null,
    "nvd_published_at" : "2017-05-11T10:29:00Z"
  }
}