CVE-2026-46148: Software Security Vulnerability Vulnerability
MODERATECVE-2026-46148 is a MODERATE (CVSS 5.5) security vulnerability vulnerability (General Security Weakness) affecting Software libraries in the Maven ecosystem. Remediation is available in the latest vendor maintenance releases.
CVE-2026-46148 at a Glance
Security Impact
CVSS: 5.5
The security impact metrics below are parsed directly from the CVSS v3.1 vector string (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H).
How to Fix CVE-2026-46148
To remediate this vulnerability, upgrade all affected Software dependencies to a patched release. Both direct and transitive dependencies should be checked, as frameworks or security libraries may pull in vulnerable versions transitively.
Run the following command in your project directory to verify that all resolved dependencies use the patched release:
mvn dependency:tree
How to Check if You Are Affected
To determine whether your Java application is affected by CVE-2026-46148, inspect your build dependencies using the Maven Dependency Plugin:
mvn dependency:tree
Analyze the terminal output to locate any version of Software in your dependency tree. If any resolved version matches the vulnerable ranges listed in the table below (for example, versions earlier than the patched release), your application is affected.
Note: The mvn dependency:tree command inspects the resolved dependency graph declared in your project's POM files; it does not perform automated security scanning or inspect runtime dynamic classpaths. Always verify runtime container classpaths and shaded JARs.
Technical Details
Vulnerability Mechanism & Technical Analysis
This vulnerability is classified under General Security Weakness. In Software, software state validation or input boundaries are circumvented during processing. Review the official source advisory statement below for specific affected components, classes, and reproduction details.
Source Advisory Statement
References
Frequently Asked Questions
What is CVE-2026-46148?
Which Software versions are affected?
What version fixes CVE-2026-46148?
What is the CVSS score of CVE-2026-46148?
What CWE is associated with CVE-2026-46148?
How can I check Maven dependencies for CVE-2026-46148?
Machine-readable OSV JSON
OSV v1.5 Schema
{
"schema_version" : "1.4.0",
"id" : "GHSA-v9m3-f9j3-xrv6",
"modified" : "2026-06-10T21:31:24Z",
"published" : "2026-05-28T12:30:30Z",
"aliases" : [ "CVE-2026-46148" ],
"details" : "In the Linux kernel, the following vulnerability has been resolved:\n\nspi: microchip-core-qspi: control built-in cs manually\n\nThe coreQSPI IP supports only a single chip select, which is\nautomagically operated by the hardware - set low when the transmit\nbuffer first gets written to and set high when the number of bytes\nwritten to the TOTALBYTES field of the FRAMES register have been sent on\nthe bus. Additional devices must use GPIOs for their chip selects.\nIt was reported to me that if there are two devices attached to this\nQSPI controller that the in-built chip select is set low while linux\ntries to access the device attached to the GPIO.\n\nThis went undetected as the boards that connected multiple devices to\nthe SPI controller all exclusively used GPIOs for chip selects, not\nrelying on the built-in chip select at all. It turns out that this was\nbecause the built-in chip select, when controlled automagically, is set\nlow when active and high when inactive, thereby ruling out its use for\nactive-high devices or devices that need to transmit with the chip\nselect disabled.\n\nModify the driver so that it controls chip select directly, retaining\nthe behaviour for mem_ops of setting the chip select active for the\nentire duration of the transfer in the exec_op callback. For regular\ntransfers, implement the set_cs callback for the core to use.\n\nAs part of this, the existing setup callback, mchp_coreqspi_setup_op(),\nis removed. Modifying the CLKIDLE field is not safe to do during\noperation when there are multiple devices, so this code is removed\nentirely. Setting the MASTER and ENABLE fields is something that can be\ndone once at probe, it doesn't need to be re-run for each device.\nInstead the new setup callback sets the built-in chip select to its\ninactive state for active-low devices, as the reset value of the chip\nselect in software controlled mode is low.",
"severity" : [ {
"type" : "CVSS_V3",
"score" : "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
} ],
"affected" : [ ],
"references" : [ {
"type" : "ADVISORY",
"url" : "https://nvd.nist.gov/vuln/detail/CVE-2026-46148"
}, {
"type" : "WEB",
"url" : "https://git.kernel.org/stable/c/7672749e1496215e8683ce57cf323119033954cf"
}, {
"type" : "WEB",
"url" : "https://git.kernel.org/stable/c/998f43196d732f20f9b71eb6ebd973736c9fa911"
}, {
"type" : "WEB",
"url" : "https://git.kernel.org/stable/c/ee3c99aa102212ad59dc2c19595515c4a6729307"
} ],
"database_specific" : {
"cwe_ids" : [ ],
"severity" : "MODERATE",
"github_reviewed" : false,
"github_reviewed_at" : null,
"nvd_published_at" : "2026-05-28T10:16:30Z"
}
}