CVE-2021-45642: Software Security Vulnerability Vulnerability

HIGH
Advisory Identifier: GHSA-6w4x-5fpc-6gg8
Published
Advisory Summary

CVE-2021-45642 is a HIGH security vulnerability vulnerability (General Security Weakness) affecting Software libraries in the Maven ecosystem. Remediation is available in the latest vendor maintenance releases.

CVE-2021-45642 at a Glance

CVE Identifier CVE-2021-45642
GHSA Identifier GHSA-6w4x-5fpc-6gg8
Severity HIGH
CVSS v3.1 Base Score N/A
CWE Classification General Security Weakness
Affected Product Software
Package Ecosystem Maven
Published Date
Last Updated

How to Fix CVE-2021-45642

To remediate this vulnerability, upgrade all affected Software dependencies to a patched release. Both direct and transitive dependencies should be checked, as frameworks or security libraries may pull in vulnerable versions transitively.

Verify Direct and Transitive Dependencies

Run the following command in your project directory to verify that all resolved dependencies use the patched release:

mvn dependency:tree

How to Check if You Are Affected

To determine whether your Java application is affected by CVE-2021-45642, inspect your build dependencies using the Maven Dependency Plugin:

mvn dependency:tree

Analyze the terminal output to locate any version of Software in your dependency tree. If any resolved version matches the vulnerable ranges listed in the table below (for example, versions earlier than the patched release), your application is affected.

Note: The mvn dependency:tree command inspects the resolved dependency graph declared in your project's POM files; it does not perform automated security scanning or inspect runtime dynamic classpaths. Always verify runtime container classpaths and shaded JARs.

Technical Details

Vulnerability Mechanism & Technical Analysis

This vulnerability is classified under General Security Weakness. In Software, software state validation or input boundaries are circumvented during processing. Review the official source advisory statement below for specific affected components, classes, and reproduction details.

Source Advisory Statement

Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7800 before 1.0.1.64, EX6250 before 1.0.0.134, EX7700 before 1.0.0.222, LBR20 before 2.6.3.50, RBS50Y before 2.7.3.22, R8900 before 1.0.5.26, R9000 before 1.0.5.26, XR450 before 2.3.2.66, XR500 before 2.3.2.66, XR700 before 1.0.1.36, EX7320 before 1.0.0.134, RAX120 before 1.2.2.24, EX7300v2 before 1.0.0.134, RAX120v2 before 1.2.2.24, EX6410 before 1.0.0.134, RBR10 before 2.7.3.22, RBR20 before 2.7.3.22, RBR40 before 2.7.3.22, RBR50 before 2.7.3.22, EX6420 before 1.0.0.134, RBS10 before 2.7.3.22, RBS20 before 2.7.3.22, RBS40 before 2.7.3.22, RBS50 before 2.7.3.22, EX6400v2 before 1.0.0.134, RBK12 before 2.7.3.22, RBK20 before 2.7.3.22, RBK40 before 2.7.3.22, and RBK50 before 2.7.3.22.

References

Frequently Asked Questions

What is CVE-2021-45642?
CVE-2021-45642 is a security vulnerability in Software classified as a security vulnerability vulnerability under General Security Weakness.
Which Software versions are affected?
Affected versions include releases prior to current release patches.
What version fixes CVE-2021-45642?
Upgrading to current release patches (or the latest patched release for your respective branch) resolves the vulnerability.
What CWE is associated with CVE-2021-45642?
CVE-2021-45642 is classified under General Security Weakness.
How can I check Maven dependencies for CVE-2021-45642?
Run the dependency tree command: 'mvn dependency:tree'. This command lists direct and transitive dependencies in your build configuration so you can verify if a vulnerable version is resolved.
Machine-readable OSV JSON OSV v1.5 Schema
Normalized schema output
{
  "schema_version" : "1.4.0",
  "id" : "GHSA-6w4x-5fpc-6gg8",
  "modified" : "2022-01-13T00:02:00Z",
  "published" : "2021-12-27T00:00:38Z",
  "aliases" : [ "CVE-2021-45642" ],
  "details" : "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7800 before 1.0.1.64, EX6250 before 1.0.0.134, EX7700 before 1.0.0.222, LBR20 before 2.6.3.50, RBS50Y before 2.7.3.22, R8900 before 1.0.5.26, R9000 before 1.0.5.26, XR450 before 2.3.2.66, XR500 before 2.3.2.66, XR700 before 1.0.1.36, EX7320 before 1.0.0.134, RAX120 before 1.2.2.24, EX7300v2 before 1.0.0.134, RAX120v2 before 1.2.2.24, EX6410 before 1.0.0.134, RBR10 before 2.7.3.22, RBR20 before 2.7.3.22, RBR40 before 2.7.3.22, RBR50 before 2.7.3.22, EX6420 before 1.0.0.134, RBS10 before 2.7.3.22, RBS20 before 2.7.3.22, RBS40 before 2.7.3.22, RBS50 before 2.7.3.22, EX6400v2 before 1.0.0.134, RBK12 before 2.7.3.22, RBK20 before 2.7.3.22, RBK40 before 2.7.3.22, and RBK50 before 2.7.3.22.",
  "severity" : [ ],
  "affected" : [ ],
  "references" : [ {
    "type" : "ADVISORY",
    "url" : "https://nvd.nist.gov/vuln/detail/CVE-2021-45642"
  }, {
    "type" : "WEB",
    "url" : "https://kb.netgear.com/000064491/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0427"
  } ],
  "database_specific" : {
    "cwe_ids" : [ ],
    "severity" : "HIGH",
    "github_reviewed" : false,
    "github_reviewed_at" : null,
    "nvd_published_at" : "2021-12-26T01:15:00Z"
  }
}