CVE-2024-33862: OPCFoundation.NetStandard.Opc.Ua.Core OPCFoundation.NetStandard.Opc.Ua.Core Buffer-management Vulnerability Vulnerability
HIGHCVE-2024-33862 is a HIGH (CVSS 7.5) opcfoundation.netstandard.opc.ua.core buffer-management vulnerability vulnerability (CWE-770: Allocation of Resources Without Limits or Throttling) affecting OPCFoundation.NetStandard.Opc.Ua.Core libraries in the NuGet ecosystem. The issue involves opcfoundation.netstandard.opc.ua.core buffer-management vulnerability. Remediation is available by upgrading affected packages to version 1.5.374.54.
CVE-2024-33862 at a Glance
Security Impact
CVSS: 7.5
The security impact metrics below are parsed directly from the CVSS v3.1 vector string (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
How to Fix CVE-2024-33862
To remediate this vulnerability, upgrade all affected OPCFoundation.NetStandard.Opc.Ua.Core dependencies to a patched release. Both direct and transitive dependencies should be checked, as frameworks or security libraries may pull in vulnerable versions transitively.
Upgrade OPCFoundation.NetStandard.Opc.Ua.Core to 1.5.374.54
Run the following command in your project directory to verify that all resolved dependencies use the patched release:
inspect dependencies for OPCFoundation.NetStandard.Opc.Ua.Core
How to Check if You Are Affected
To determine whether your application is affected by CVE-2024-33862, inspect your project dependencies for OPCFoundation.NetStandard.Opc.Ua.Core:
inspect dependencies for OPCFoundation.NetStandard.Opc.Ua.Core
Analyze the terminal output to locate any version of OPCFoundation.NetStandard.Opc.Ua.Core in your dependency tree. If any resolved version matches the vulnerable ranges listed in the table below (for example, versions earlier than 1.5.374.54), your application is affected.
Note: Verify declared build manifests and deployed runtime container environments.
Technical Details
Vulnerability Mechanism & Technical Analysis
This vulnerability is classified under CWE-770: Allocation of Resources Without Limits or Throttling, where the product allocates a reusable resource or group of resources on behalf of an actor without imposing any intended restrictions on the size or number of resources that can be allocated. In OPCFoundation.NetStandard.Opc.Ua.Core, software state validation or input boundaries are circumvented during processing. Review the official source advisory statement below for specific affected components, classes, and reproduction details.
Source Advisory Statement
CVE-2024-33862 Affected OPCFoundation.NetStandard.Opc.Ua.Core Versions
1 component(s)| Product / Package | Ecosystem | Affected Versions | Fixed Version |
|---|---|---|---|
|
OPCFoundation.NetStandard.Opc.Ua.Core
|
NuGet |
< 1.5.374.54
|
1.5.374.54
|
References
Frequently Asked Questions
What is CVE-2024-33862?
Which OPCFoundation.NetStandard.Opc.Ua.Core versions are affected?
What version fixes CVE-2024-33862?
Is OPCFoundation.NetStandard.Opc.Ua.Core affected?
What is the CVSS score of CVE-2024-33862?
What CWE is associated with CVE-2024-33862?
How can I check NuGet dependencies for CVE-2024-33862?
Machine-readable OSV JSON
OSV v1.5 Schema
{
"schema_version" : "1.4.0",
"id" : "GHSA-4q2p-hwmr-qcxc",
"modified" : "2024-07-08T14:21:37Z",
"published" : "2024-07-06T00:31:06Z",
"aliases" : [ "CVE-2024-33862" ],
"summary" : "OPCFoundation.NetStandard.Opc.Ua.Core buffer-management vulnerability",
"details" : "A buffer-management vulnerability in OPC Foundation OPCFoundation.NetStandard.Opc.Ua.Core before 1.5.374.54 could allow remote attackers to exhaust memory resources. It is triggered when the system receives an excessive number of messages from a remote source. This could potentially lead to a denial of service (DoS) condition, disrupting the normal operation of the system.",
"severity" : [ {
"type" : "CVSS_V3",
"score" : "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}, {
"type" : "CVSS_V4",
"score" : "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N"
} ],
"affected" : [ {
"package" : {
"ecosystem" : "NuGet",
"name" : "OPCFoundation.NetStandard.Opc.Ua.Core"
},
"ranges" : [ {
"type" : "ECOSYSTEM",
"events" : [ {
"introduced" : "0"
}, {
"fixed" : "1.5.374.54"
} ]
} ]
} ],
"references" : [ {
"type" : "ADVISORY",
"url" : "https://nvd.nist.gov/vuln/detail/CVE-2024-33862"
}, {
"type" : "WEB",
"url" : "https://github.com/OPCFoundation/UA-.NETStandard/commit/52d4492ccc928f128e7a38857fdf58d94e1e652b"
}, {
"type" : "WEB",
"url" : "https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2024-33862.pdf"
}, {
"type" : "PACKAGE",
"url" : "https://github.com/OPCFoundation/UA-.NETStandard"
}, {
"type" : "WEB",
"url" : "https://github.com/OPCFoundation/UA-.NETStandard/releases/tag/1.5.374.54"
} ],
"database_specific" : {
"cwe_ids" : [ "CWE-770" ],
"severity" : "HIGH",
"github_reviewed" : true,
"github_reviewed_at" : "2024-07-08T14:21:37Z",
"nvd_published_at" : "2024-07-05T23:15:10Z"
}
}