CVE-2023-32735: Software Security Vulnerability Vulnerability

HIGH
Advisory Identifier: GHSA-27hg-xg89-rq4f
CVSS 6.5
CWE-502
Published
Advisory Summary

CVE-2023-32735 is a HIGH (CVSS 6.5) security vulnerability vulnerability (CWE-502: Deserialization of Untrusted Data) affecting Software libraries in the Maven ecosystem. The weakness occurs when the product deserializes untrusted data without sufficiently ensuring that the resulting data will be valid.. Remediation is available in the latest vendor maintenance releases.

CVE-2023-32735 at a Glance

CVE Identifier CVE-2023-32735
GHSA Identifier GHSA-27hg-xg89-rq4f
Severity HIGH
CVSS v3.1 Base Score 6.5
CWE Classification CWE-502: Deserialization of Untrusted Data
Affected Product Software
Package Ecosystem Maven
Published Date
Last Updated

Security Impact

CVSS: 6.5

The security impact metrics below are parsed directly from the CVSS v3.1 vector string (CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H).

Attack Vector Local (AV:L)
Attack Complexity Low (AC:L)
Privileges Required High (PR:H)
User Interaction Required (UI:R)
Scope Unchanged (S:U)
Confidentiality High (C:H)
Integrity High (I:H)
Availability High (A:H)

How to Fix CVE-2023-32735

To remediate this vulnerability, upgrade all affected Software dependencies to a patched release. Both direct and transitive dependencies should be checked, as frameworks or security libraries may pull in vulnerable versions transitively.

Verify Direct and Transitive Dependencies

Run the following command in your project directory to verify that all resolved dependencies use the patched release:

mvn dependency:tree

How to Check if You Are Affected

To determine whether your Java application is affected by CVE-2023-32735, inspect your build dependencies using the Maven Dependency Plugin:

mvn dependency:tree

Analyze the terminal output to locate any version of Software in your dependency tree. If any resolved version matches the vulnerable ranges listed in the table below (for example, versions earlier than the patched release), your application is affected.

Note: The mvn dependency:tree command inspects the resolved dependency graph declared in your project's POM files; it does not perform automated security scanning or inspect runtime dynamic classpaths. Always verify runtime container classpaths and shaded JARs.

Technical Details

Vulnerability Mechanism & Technical Analysis

This vulnerability is classified under CWE-502: Deserialization of Untrusted Data, where the product deserializes untrusted data without sufficiently ensuring that the resulting data will be valid. In Software, software state validation or input boundaries are circumvented during processing. Review the official source advisory statement below for specific affected components, classes, and reproduction details.

Source Advisory Statement

A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions < V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2), SIMATIC STEP 7 V16 (All versions < V16 Update 7), SIMATIC STEP 7 V17 (All versions < V17 Update 7), SIMATIC STEP 7 V18 (All versions < V18 Update 2), SIMATIC WinCC Unified V16 (All versions < V16 Update 7), SIMATIC WinCC Unified V17 (All versions < V17 Update 7), SIMATIC WinCC Unified V18 (All versions < V18 Update 2), SIMATIC WinCC V16 (All versions < V16.7), SIMATIC WinCC V17 (All versions < V17.7), SIMATIC WinCC V18 (All versions < V18 Update 2), SIMOCODE ES V16 (All versions < V16 Update 7), SIMOCODE ES V17 (All versions < V17 Update 7), SIMOCODE ES V18 (All versions < V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions < V17 Update 7), SIRIUS Safety ES V18 (All versions < V18 Update 2), SIRIUS Soft Starter ES V17 (All versions < V17 Update 7), SIRIUS Soft Starter ES V18 (All versions < V18 Update 2), Soft Starter ES V16 (All versions < V16 Update 7), TIA Portal Cloud V3.0 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.

References

Frequently Asked Questions

What is CVE-2023-32735?
CVE-2023-32735 is a security vulnerability in Software classified as a security vulnerability vulnerability under CWE-502: Deserialization of Untrusted Data.
Which Software versions are affected?
Affected versions include releases prior to current release patches.
What version fixes CVE-2023-32735?
Upgrading to current release patches (or the latest patched release for your respective branch) resolves the vulnerability.
What is the CVSS score of CVE-2023-32735?
CVE-2023-32735 has a CVSS v3.1 base score of 6.5 (HIGH) with vector string CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H.
What CWE is associated with CVE-2023-32735?
CVE-2023-32735 is classified under CWE-502: Deserialization of Untrusted Data (The product deserializes untrusted data without sufficiently ensuring that the resulting data will be valid.).
How can I check Maven dependencies for CVE-2023-32735?
Run the dependency tree command: 'mvn dependency:tree'. This command lists direct and transitive dependencies in your build configuration so you can verify if a vulnerable version is resolved.
Machine-readable OSV JSON OSV v1.5 Schema
Normalized schema output
{
  "schema_version" : "1.4.0",
  "id" : "GHSA-27hg-xg89-rq4f",
  "modified" : "2024-07-09T12:30:57Z",
  "published" : "2024-07-09T12:30:57Z",
  "aliases" : [ "CVE-2023-32735" ],
  "details" : "A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions < V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2), SIMATIC STEP 7 V16 (All versions < V16 Update 7), SIMATIC STEP 7 V17 (All versions < V17 Update 7), SIMATIC STEP 7 V18 (All versions < V18 Update 2), SIMATIC WinCC Unified V16 (All versions < V16 Update 7), SIMATIC WinCC Unified V17 (All versions < V17 Update 7), SIMATIC WinCC Unified V18 (All versions < V18 Update 2), SIMATIC WinCC V16 (All versions < V16.7), SIMATIC WinCC V17 (All versions < V17.7), SIMATIC WinCC V18 (All versions < V18 Update 2), SIMOCODE ES V16 (All versions < V16 Update 7), SIMOCODE ES V17 (All versions < V17 Update 7), SIMOCODE ES V18 (All versions < V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions < V17 Update 7), SIRIUS Safety ES V18 (All versions < V18 Update 2), SIRIUS Soft Starter ES V17 (All versions < V17 Update 7), SIRIUS Soft Starter ES V18 (All versions < V18 Update 2), Soft Starter ES V16 (All versions < V16 Update 7), TIA Portal Cloud V3.0 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.\n\nThis is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.",
  "severity" : [ {
    "type" : "CVSS_V3",
    "score" : "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H"
  }, {
    "type" : "CVSS_V4",
    "score" : "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X"
  } ],
  "affected" : [ ],
  "references" : [ {
    "type" : "ADVISORY",
    "url" : "https://nvd.nist.gov/vuln/detail/CVE-2023-32735"
  }, {
    "type" : "WEB",
    "url" : "https://cert-portal.siemens.com/productcert/html/ssa-779936.html"
  } ],
  "database_specific" : {
    "cwe_ids" : [ "CWE-502" ],
    "severity" : "HIGH",
    "github_reviewed" : false,
    "github_reviewed_at" : null,
    "nvd_published_at" : "2024-07-09T12:15:09Z"
  }
}